Difference between revisions of "Biomass Boiler"

 
Line 1: Line 1:
 
{{Biomass Boiler
 
{{Biomass Boiler
|Description=(empty)
+
|Description=
|Advantages=(empty)
+
|Advantages=
|Disadvantages=(empty)
+
|Disadvantages=
|Application barriers=(empty)
+
|Application barriers=
|Information sources=(empty)
+
|Information sources=
|Image=(empty)
+
|Image=
|Trade=(empty)
+
|Trade=
|Fuel=(empty)
+
|FuelMin=Wood Pellet
|Input Capacity=(empty)
+
|FuelMax=Wood chips
|Output Capacity=(empty)
+
|Input CapacityMin=
|Water Capacity=(empty)
+
|Input CapacityMax=
|Water Flow Temperature (Maximum/Minimum)=(empty)
+
|Output CapacityMin=3.9
|Water Return Temperature (Maximum/Minimum)=(empty)
+
|Output CapacityMax=75
|Operating Pressure=(empty)
+
|Water CapacityMin=55
|Heating Surface=(empty)
+
|Water CapacityMax=256
|Operating Efficiency=(empty)
+
|Water Flow Temperature (Maximum/Minimum)Min=50
|Annual Degradation Rate in Efficiency=(empty)
+
|Water Flow Temperature (Maximum/Minimum)Max=95
|Dimensions=(empty)
+
|Water Return Temperature (Maximum/Minimum)Min=40
|Weight=(empty)
+
|Water Return Temperature (Maximum/Minimum)Max=55
|Noise Level=(empty)
+
|Operating PressureMin=
|Maximum CO Emission=(empty)
+
|Operating PressureMax=3.0
|Maximum NOX Emission=(empty)
+
|Heating SurfaceMin=
|Investment Cost=(empty)
+
|Heating SurfaceMax=
|Operational Cost=(empty)
+
|Operating EfficiencyMin=89
|Replacement Cost=(empty)
+
|Operating EfficiencyMax=91
|Life Expectancy=(empty)
+
|Annual Degradation Rate in EfficiencyMin=
}}
+
|Annual Degradation Rate in EfficiencyMax=
 
+
|DimensionsMin=865/590/1168
Properties:
+
|DimensionsMax=1774/1090/1810
[[Category:Boiler Technologies]]
+
|WeightMin=261
[[class::Boiler Technologies]]
+
|WeightMax=890
[[relevance::1]]
+
|Noise LevelMin=
[[importance::1]]
+
|Noise LevelMax=
[[efficiency::1]]
+
|Maximum CO EmissionMin=
 +
|Maximum CO EmissionMax=
 +
|Maximum NOX EmissionMin=
 +
|Maximum NOX EmissionMax=
 +
|Investment CostMin=4,640
 +
|Investment CostMax=9,280
 +
|Operational CostMin=2,900
 +
|Operational CostMax=
 +
|Maintenance CostMin=174
 +
|Maintenance CostMax=579
 +
|Life ExpectancyMin=18
 +
|Life ExpectancyMax=20
 +
|}}

Latest revision as of 11:42, 7 February 2017


[edit]
Description
Advantages
Disadvantages
Characteristic features
Application barriers
Information sources
Image
Trade:
Parameter Minimal Value Maximal Value Unit
Fuel

Wood Pellet

Wood chips

Input Capacity

kW

Output Capacity

3.9

75

kW

Water Capacity

55

256

l

Water Flow Temperature (Maximum/Minimum)

50

95

°C

Water Return Temperature (Maximum/Minimum)

40

55

°C

Operating Pressure

3.0

Bar

Heating Surface

mm²

Operating Efficiency

89

91

%

Annual Degradation Rate in Efficiency

%

Dimensions

865/590/1168

1774/1090/1810

L/W/H in mm

Weight

261

890

kg

Noise Level

dBA

Maximum CO Emission

ppm

Maximum NOX Emission

ppm

Investment Cost

4,640

9,280

Operational Cost

2,900

€/year

Maintenance Cost

174

579

€/year

Life Expectancy

18

20

years

Deterioration Description
Causes
Parameter
Degradation Rate
Measurement


The Design4Energy project aims to address evolutionary life-cycle evolutionary design methodology able to create energy-efficient buildings flexibly connected with the neighbourhood energy system. BrokenWall.JPG
BL(Ti)=0.788
Equation.JPG


pCghffhfhart