Brick Wall


[edit]
Description
Advantages
Disadvantages
Characteristic features
Application barriers
Information sources
Image
Trade:
Parameter Minimal Value Maximal Value Unit
Name

WBUITBL (IES database)

WALLSLCD (IES database)

Material

BRICKWORK (OUTER LEAF), UF FOAM, THERMALITE - HIGH STRENGTH, PLASTER (LIGHTWEIGHT)

BRICKWORK (OUTER LEAF), PLASTER (DENSE)

Dimensions

L/W = na

L/W = na

m

Thickness

0.268

0.233

m

Weight

262.8

390.9

kg/m²

Density

Can be derived from materials if needed

Can be derived from materials if needed

kg/m³

U-Value - Thermal Transmittance

0.4646

2.1839

W/m2K

Annual Degradation Rate on U-Value

+0.35% (estimated based on degradation of insulation)

+0.05% (estimated based on degradation of insulation)

%

R-Value

2.16

0.465

Thermal Conductivity

Can be derived from materials if needed

Can be derived from materials if needed

W/mK

Specific Heat Capacity Thermal mass

77.226

135.22

kJ/kgK kJ/(m2K)

Solar Heat Gain Coefficient

na

na

%

Solar Absorption (outside surface)

0.7

0.7

Orientation

na

na

Investment Cost

300 (estimated)

50-100 (estimated)

€/m2

Operational Cost

na

na

€/year

Replacement Cost

na

na

€/year

Life Expectancy

86 (building component life expectancy source)

86 (building component life expectancy source)

years

Deterioration Description
Causes
Parameter
Degradation Rate
Measurement


The Design4Energy project aims to address evolutionary life-cycle evolutionary design methodology able to create energy-efficient buildings flexibly connected with the neighbourhood energy system. BrokenWall.JPG
BL(Ti)=0.788
Equation.JPG


pCghffhfhart