Trade:
Parameter Minimal Value Maximal Value Unit
Fuel

Natural Gas, Wood pellets, Biofuel, Biodiesel, Extra Light Fuel Oil, Propane

Electrical Output

0.3

30

kW

Heating Capacity

3.25

61.6

kW

Electrical Efficiency

20

33.5

%

Thermal Efficiency

51.5

69.3

%

Maximum Working Pressure

2

600

kPa

Heating Flow Temperature

25

85

°C

Operating Efficiency

84.2

95.3

%

Annual Degradation Rate in Efficiency

%

Dimensions

38/58/88

2150/900/2060

L/W/H in mm

Weight

81

1320

kg

Noise Level

44

65

dBA

Maximum CO Emission

300

500

mg/Nm3

Maximum NOX Emission

70

250

mg/Nm3

Investment Cost

5,800

8,120

Operating Cost

182.12

203

€/kW

Maintenance Cost

1.02

2.42

Cent/kWh

Life Expectancy

50,000

60,000

hours