Difference between revisions of "Movable and Frameless Window"

Line 16: Line 16:
 
|Sound InsulationMin=42
 
|Sound InsulationMin=42
 
|Sound InsulationMax=40
 
|Sound InsulationMax=40
|Thermal ConductivityMin=1.01
+
|Thermal ConductivityMin=1,01
|Thermal ConductivityMax=0.78
+
|Thermal ConductivityMax=0,78
 
|Specific Heat CapacityMin=n.a.
 
|Specific Heat CapacityMin=n.a.
 
|Specific Heat CapacityMax=n.a.
 
|Specific Heat CapacityMax=n.a.
Line 32: Line 32:
 
|Number of GlazingMin=2
 
|Number of GlazingMin=2
 
|Number of GlazingMax=3
 
|Number of GlazingMax=3
|U-ValueMin=0.7
+
|U-ValueMin=0,7
|U-ValueMax=0.7
+
|U-ValueMax=0,7
 
|Annual Degradation Rate on U-ValueMin=1
 
|Annual Degradation Rate on U-ValueMin=1
 
|Annual Degradation Rate on U-ValueMax=1
 
|Annual Degradation Rate on U-ValueMax=1
Line 46: Line 46:
 
|Area Frame/WindowMin=17
 
|Area Frame/WindowMin=17
 
|Area Frame/WindowMax=7
 
|Area Frame/WindowMax=7
|U-ValueMin=0.9
+
|U-ValueMin=0,9
|U-ValueMax=0.9
+
|U-ValueMax=0,9
 
|Annual Degradation Rate on U-ValueMin=0
 
|Annual Degradation Rate on U-ValueMin=0
 
|Annual Degradation Rate on U-ValueMax=0
 
|Annual Degradation Rate on U-ValueMax=0

Revision as of 15:14, 2 February 2017



[edit]
Description
Advantages
Disadvantages
Application barriers
Information sources
Image
Trade:


Parameter Minimal Value Maximal Value Unit
Dimensions

1200/2000

6000/4000

mm

Thickness

150

150

mm

Infiltration Rate

4

3

m³/hm²

Sound Insulation

42

40

dBA

Thermal Conductivity

1,01

0,78

W/mK

Specific Heat Capacity

n.a.

n.a.

J/kgK

Associated Wall

any

any

Investment Cost

1500

1500

€/m²

Operational Cost

3

3

€/m²year

Replacement Cost

33,75

45

€/m²year

Life Expectancy

30

30

years

Number of Glazing

2

3

U-Value

0,9

0,9

W/m²K

Annual Degradation Rate on U-Value

0

0

%

g-Value (depending on used glass)

52

52

%

Solar Heat Gain Coefficient

40

40

%

Visual Light Transmittance (depending on used glass)

69

69

%

Material

glas fibre reinforced Polyester

glas fibre reinforced Polyester

Area Frame/Window

17

7

%

U-Value

0,9

0,9

W/m²K

Annual Degradation Rate on U-Value

0

0

%

Solar Absorbance

n.a.

n.a.

Deterioration Description
Causes
Parameter
Degradation Rate
Measurement


The Design4Energy project aims to address evolutionary life-cycle evolutionary design methodology able to create energy-efficient buildings

flexibly connected with the neighbourhood energy system.

BrokenWall.JPG
BL(Ti)=0.788
Equation.JPG


pCghffhfhart