SATE/ETICS ROCKWOOL facade energy refurbishment system


[edit]
Description
Advantages
Disadvantages
Characteristic features
Application barriers
Information sources
Image
Trade:
Parameter Minimal Value Maximal Value Unit
Name

SATE/ETICS

N/A

Material

ROCKWOOL,

Dimensions

N/A

N/A

m

Thickness

0,1

0,3

m

Weight

0,6

0,6

kg/m²

Density

N/A (multilayer)

N/A (multilayer)

kg/m³

U-Value - Thermal Transmittance

0,74

0,13

W/m2K

Annual Degradation Rate on U-Value

1

1

%

R-Value

1,35

7,2

Thermal Conductivity

0,5

W/mK

Specific Heat Capacity Thermal mass

kJ/kgK kJ/(m2K)

Solar Heat Gain Coefficient

N/A

N/A

%

Solar Absorption (outside surface)

0,4

0,8

Orientation

N/A

N/A

Investment Cost

59

122

€/m2

Operational Cost

0

0

€/year

Replacement Cost

90

160

€/year

Life Expectancy

30

30

years

Deterioration Description
Causes

sun radiation, temperature variations, structural movement, mechanical stress

Parameter

U-value, water storage, waterproofing, air infiltration

Degradation Rate

0-1

Measurement

onsite testing, energy monitoring


The Design4Energy project aims to address evolutionary life-cycle evolutionary design methodology able to create energy-efficient buildings flexibly connected with the neighbourhood energy system. BrokenWall.JPG
BL(Ti)=0.788
Equation.JPG


pCghffhfhart