Browse wiki

SATE/ETICS ROCKWOOL facade energy refurbishment system
Annual Degradation Rate on U-ValueMax 1  +
Annual Degradation Rate on U-ValueMin 1  +
Causes Sun radiation, temperature variations, structural movement, mechanical stress  +
Degradation Rate 0-1  +
DensityMax N/A (multilayer)  +
DensityMin N/A (multilayer)  +
DimensionsMax N/A  +
DimensionsMin N/A  +
Investment CostMax 122  +
Investment CostMin 59  +
Life ExpectancyMax 30  +
Life ExpectancyMin 30  +
MaterialMin ROCKWOOL,  +
Measurement Onsite testing, energy monitoring  +
NameMax N/A  +
NameMin SATE/ETICS  +
Operational CostMax 0  +
Operational CostMin 0  +
OrientationMax N/A  +
OrientationMin N/A  +
Parameter U-value, water storage, waterproofing, air infiltration  +
R-ValueMax 7,2  +
R-ValueMin 1,35  +
Replacement CostMax 160  +
Replacement CostMin 90  +
Solar Absorption (outside surface)Max 0,8  +
Solar Absorption (outside surface)Min 0,4  +
Solar Heat Gain CoefficientMax N/A  +
Solar Heat Gain CoefficientMin N/A  +
Thermal ConductivityMin 0,5  +
ThicknessMax 0,3  +
ThicknessMin 0,1  +
U-Value - Thermal TransmittanceMax 0,13  +
U-Value - Thermal TransmittanceMin 0,74  +
WeightMax 0,6  +
WeightMin 0,6  +