Difference between revisions of "Timber Framed Internal Window - Double"
(Created page with "{{Building component |Description= |Advantages= |Disadvantages= |Application barriers= |Information sources=http://www.revitcity.com/downloads.php?action=view&object_id=8055 |...") |
|||
(7 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
− | {{ | + | {{Window |
− | |Description= | + | |Description=Parametric Timber Framed Internal Window - Double Bay |
− | | | + | CSI Division: 08 52 00 Wood Windows |
− | | | + | RevitCity Division: Windows > Miscellaneous |
− | | | + | Product Version: Revit Architecture 2010 |
+ | Uploaded By: Johnboy | ||
+ | Uploaded On: Tue, Oct 6, 2009 | ||
+ | Original Creator: Johnboy | ||
+ | |Investment Cost=300 | ||
+ | |Life Expectancy=12 | ||
+ | |Image=8055.jpg | ||
+ | |Trade= | ||
|Information sources=http://www.revitcity.com/downloads.php?action=view&object_id=8055 | |Information sources=http://www.revitcity.com/downloads.php?action=view&object_id=8055 | ||
− | | | + | |Dimensions= |
− | | | + | |Thickness=40 |
− | | | + | |Infiltration Rate= |
− | | | + | |Sound Insulation= |
− | | | + | |Thermal Conductivity= |
− | | | + | |Specific Heat Capacity= |
− | | | + | |Number of Glazing=2 |
− | | | + | |U-Value=5.2 |
− | | | + | |Annual Degradation Rate on U-Value=99 |
− | | | + | |g-Value= |
− | | | + | |Solar Heat Gain Coefficient= |
+ | |Visual Light Transmittance= | ||
+ | |Material= | ||
}} | }} | ||
+ | |||
+ | Properties | ||
+ | [[relevance::8]] | ||
+ | [[symbol::2]] | ||
+ | [[Category:Window]] | ||
+ | [[Category:Standard]] | ||
+ | [[importance::1]] | ||
+ | [[class::4]] |
Latest revision as of 13:10, 1 March 2017
[edit]
Parameter | Value | Unit |
---|---|---|
Description | Parametric Timber Framed Internal Window - Double Bay
CSI Division: 08 52 00 Wood Windows RevitCity Division: Windows > Miscellaneous Product Version: Revit Architecture 2010 Uploaded By: Johnboy Uploaded On: Tue, Oct 6, 2009 Original Creator: Johnboy |
|
Investment Cost | 300 | € |
Life Expectancy | 12 | years |
Image | ![]() |
|
Trade: | ||
Information sources | http://www.revitcity.com/downloads.php?action=view&object_id=8055 |
Parameter | Value | Unit |
---|---|---|
Dimensions: | mm | |
Thickness: | 40 | mm |
Infiltration Rate: | m³/hm² | |
Sound Insulation: | dBA | |
Thermal Conductivity: | W/mK | |
Specific Heat Capacity: | J/kgK | |
Number of Glazing: | 2 | |
U-Value: | 5.2 | W/m2K |
Annual Degradation Rate on U-Value: | 99 | % |
g-Value: | % | |
Solar Heat Gain Coefficient: | % | |
Visual Light Transmittance: | % | |
Material: |
The Design4Energy project aims to address evolutionary life-cycle evolutionary design methodology able to create energy-efficient buildings flexibly connected with the neighbourhood energy system. | Form:Http://studiowta.com/wp-content/uploads/2013/03/6.jpg |
BL(Ti)=0.788 |
---|