Vacuumed Insulation Panel

Revision as of 16:19, 27 April 2017 by Design4Energy (Talk | contribs)


[edit]
Description
Advantages
Disadvantages
Characteristic features
Application barriers
Information sources
Image
Trade:
Parameter Minimal Value Maximal Value Unit
Name
Material
Dimensions

300/600

1000/600

m

Thickness

0,21

0,22

m

Weight

433

433

kg/m²

Density

2400

2400

kg/m³

U-Value - Thermal Transmittance

0,32

0,22

W/m2K

Annual Degradation Rate on U-Value

n.a.

n.a.

%

R-Value
Thermal Conductivity

0,007

0,007

W/mK

Specific Heat Capacity Thermal mass

1,05

1,05

kJ/kgK kJ/(m2K)

Solar Heat Gain Coefficient

n.a.

n.a.

%

Solar Absorption (outside surface)

n.a.

Orientation
Investment Cost

195

225

€/m2

Operational Cost

0

0

€/year

Replacement Cost

4

7

€/year

Life Expectancy

30

50

years

Deterioration Description
Causes
Parameter
Degradation Rate
Measurement


The Design4Energy project aims to address evolutionary life-cycle evolutionary design methodology able to create energy-efficient buildings flexibly connected with the neighbourhood energy system. BrokenWall.JPG
BL(Ti)=0.788
Equation.JPG


pCghffhfhart